Skip Navigation



Annals of Occupational Hygiene Advance Access published online on October 14, 2006

Annals of Occupational Hygiene, doi:10.1093/annhyg/mel073
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
51/2/143    most recent
mel073v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Burton, N. C.
Right arrow Articles by Reponen, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Burton, N. C.
Right arrow Articles by Reponen, T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published by Oxford University Press
Received June 8, 2006
Accepted September 20, 2006

Article

Physical Collection Efficiency of Filter Materials for Bacteria and Viruses

Nancy Clark Burton 1 *, Sergey A. Grinshpun 2, and Tiina Reponen 2

1 Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, 4676 Columbia Parkway, MS R-11, Cincinnati, OH, 45226, USA; Department of Environmental Health, University of Cincinnati, PO Box 670056, Cincinnati, OH 45267, USA
2 Department of Environmental Health, University of Cincinnati, PO Box 670056, Cincinnati, OH 45267, USA

* To whom correspondence should be addressed.
Nancy Clark Burton, E-mail: NBurton{at}cdc.gov


   Abstract

The purpose of this study was to determine the physical collection efficiency of commercially available filters for collecting airborne bacteria, viruses, and other particles in the 10-900 nm (nanometer) size range. Laboratory experiments with various polytetrafluoroethylene (PTFE), polycarbonate (PC) and gelatin filters in conjunction with ButtonTM Inhalable samplers and three-piece cassettes were undertaken. Both biological and non-biological test aerosols were used: Bacillus atrophaeus, MS2, polystyrene latex (PSL), and sodium chloride (NaCl). The B.atrophaeus endospores had an aerodynamic diameter of 900 nm, whereas MS2 virion particles ranged from 10 to 80 nm. Monodisperse 350 nm PSL particles were used as this size was believed to have the lowest filtration efficiency. NaCl solution (1% weight by volume) was used to create a polydisperse aerosol in the 10-600 nm range. The physical collection efficiency was determined by measuring particle concentrations size-selectively upstream and downstream of the filters. The PTFE and gelatin filters showed excellent collection efficiency (>93%) for all of the test particles. The PC filters showed lower collection efficiency for small particles especially <100 nm. Among the tested filters, the lowest collection efficiencies, 49 and 22%, were observed for 1 and 3-µm pore size PC filters at the particle sizes of 47 and 63 nm, respectively. The results indicate that the effect of filter material is more significant for the size range of single virions than for bacteria. The effect of filter loading was examined by exposing filters to mixtures of PSL particles, which aimed at mimicking typical indoor dust levels and size distributions. A 4-h loading did not cause significant change in the physical collection efficiency of the tested filters.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Appl. Environ. Microbiol.Home page
L. Garnier, J.-C. Gaudin, P. Bensadoun, I. Rebillat, and Y. Morel
Real-Time PCR Assay for Detection of a New Simulant for Poxvirus Biothreat Agents
Appl. Envir. Microbiol., March 15, 2009; 75(6): 1614 - 1620.
[Abstract] [Full Text] [PDF]


Home page
Microbiol. Mol. Biol. Rev.Home page
D. Verreault, S. Moineau, and C. Duchaine
Methods for Sampling of Airborne Viruses
Microbiol. Mol. Biol. Rev., September 1, 2008; 72(3): 413 - 444.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.