Skip Navigation


Annals of Occupational Hygiene Advance Access originally published online on May 14, 2009
Annals of Occupational Hygiene 2009 53(5):523-538; doi:10.1093/annhyg/mep025
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
53/5/523    most recent
mep025v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Currie, J.
Right arrow Articles by Anthony, T. R.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Currie, J.
Right arrow Articles by Anthony, T. R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© The Author 2009. Published by Oxford University Press on behalf of the British Occupational Hygiene Society

The Evaluation of CBRN Canisters for Use by Firefighters during Overhaul

Jennifer Currie1, Delayne Caseman1 and T. Renee Anthony2,*

1 Mel and Enid Zuckerman College of Public Health, University of Arizona, 1295 North Martin Avenue, Tucson, AZ 85723-5210, USA
2 Occupational and Environmental Health, College of Public Health, 100 Oakdale Campus, 108 IREH, Iowa City, IA 52242-5000, USA

* Author to whom correspondence should be addressed. Tel: +319-335-4429; e-mail: renee-anthony{at}uiowa.edu

Air-purifying respirators (APRs) have been proposed to provide an additional respiratory protection option for structural firefighters involved in overhaul operations and wildland firefighters, where particulate and aldehyde exposures have been documented. Previous studies (Anthony et al., 2007) developed test methods to evaluate APR cartridges and canisters for use in overhaul activities, where initial findings indicated that multi-gas cartridges may not be effective. This study evaluated the performance of three chemical, biological, radiological, and nuclear (CBRN) canisters (MSA, 3M, and Scott) and one multi-gas canister similar in appearance to CBRN canisters but without CBRN certification (3M FR-64040). Challenge concentrations typical of overhaul exposures were generated by combusting common household materials. Twelve tests were conducted, using random canister selection, where challenge air and air filtered by the canisters were tested. All tests examined penetration of CO; NO2; SO2; respirable dust; aldehydes, including formaldehyde, acrolein, and glutaraldehyde; and hydrogen cyanide. Six of the tests also investigated naphthalene, benzene, and hydrogen chloride, but challenge concentrations from the simulated overhaul smoke were near the limit of detection (LOD) and were two orders of magnitude below short-term or ceiling concentrations of concern and were eliminated from further study with the combustion materials used in this study. In all tests, an irritant index was computed to evaluate the aggregate penetration of contaminants in the smoke mixture, using 15- and 30-min occupational exposure limits as well as assessing individual penetrations. In all cases, the challenge concentration irritant index exceeded unity, ranging from 2.3 to 21. For all 12 tests, the APR canister reduced the overall irritant index to levels below unity, indicating that these canisters would provide protection for firefighters working in overhaul environments. However, in some tests, levels of carbon monoxide were higher than recommended for persons wearing APRs. Since these canisters do not protect against carbon monoxide, firefighters must still rely on direct reading warning to indicate high CO levels, indicating the need to leave the area if wearing an APR, as these APR canisters would be inappropriate.

Keywords: CBRN • firefighter • penetration • respirator testing

Received November 25, 2008; in final form March 2, 2009


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.