Skip Navigation


Annals of Occupational Hygiene Advance Access originally published online on March 7, 2008
Annals of Occupational Hygiene 2008 52(3):167-176; doi:10.1093/annhyg/men004
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrowOA All Versions of this Article:
52/3/167    most recent
men004v2
men004v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Google Scholar
Right arrow Articles by Madsen, A. M.
Right arrow Articles by Sharma, A. K.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Madsen, A. M.
Right arrow Articles by Sharma, A. K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© 2008 The Author(s).
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/2.0/uk/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Sampling of High Amounts of Bioaerosols Using a High-Volume Electrostatic Field Sampler

A. M. Madsen1,* and A. K. Sharma2

1 The National Research Centre for the Working Environment, Lersø Parkallé 105, 2100 Copenhagen Ø, Denmark
2 National Food Institute. Technical University of Denmark, Mørkhøj Bygade 19, 2860 Søborg, Denmark

* Author to whom correspondence should be addressed. Tel: 0045 39165242; fax: 0045 39165201; e-mail: amm{at}nrcwe.dk

For studies of the biological effects of bioaerosols, large samples are necessary. To be able to sample enough material and to cover the variations in aerosol content during and between working days, a long sampling time is necessary. Recently, a high-volume transportable electrostatic field sampler for collection of fine particles has been described. The aim of this study was to investigate whether this sampler can be used for collection of high amounts of authentic bioaerosols that can subsequently be used for biological analysis. The investigation was carried out at a biofuel plant in a straw storage room and in a boiler room over two seasons. The sampled dust was quantified in terms of mass and characterized regarding microbial components and compared with dust sampled by Gravikon and GSP samplers. For the electrostatic field sampler, a prefilter was used to remove large objects. The prefilter was characterized for particle penetration and this testing indicated that the prefilter did not remove particles up to 10 µm, and therefore respirable dust was sampled by the electrostatic field sampler. Using the electrostatic field sampler in the straw storage and in the boiler room, 330 and 315 mg dust (net recovery of the lyophilized dust) was sampled during a period of 7 days, respectively. The sampling rates of the electrostatic field samplers were between 1.34 and 1.96 mg dust per hour, the value for the Gravikon was between 0.083 and 0.108 mg dust per hour and the values for the GSP samplers were between 0.0031 and 0.032 mg dust per hour. The standard deviations of replica samplings and the following microbial analysis using the electrostatic field sampler and GSP samplers were at the same levels. The exposure to dust in the straw storage was 7.7 mg m–3 when measured by the electrostatic field sampler and 11.8 mg m–3 when measured by the GSP inhalable dust sampler. The quantity (amount per mg dust) of total fungi, Aspergillus fumigatus, total bacteria, endotoxin and mesophilic actinomycetes sampled by the electrostatic field samplers and the Gravikon samplers varied within the same season by a factor smaller than four. The quantities of some microbial components were higher in the dust collected with all samplers in March than in August. In conclusion, by using the electrostatic field sampler, it was possible to sample replicas of large authentic aerosol samples that can be used, e.g. biological analysis. (Sharma AK et al., 2007a).

Keywords: aerosol sampling • bacteria • biofuel • electrostatic field sampler • endotoxin • fungi

Received September 12, 2007; in final form January 18, 2008


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.