Skip Navigation

Annals of Occupational Hygiene 2007 51(8):679-691; doi:10.1093/annhyg/mem047
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Thorpe, A.
Right arrow Articles by Walsh, P. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Thorpe, A.
Right arrow Articles by Walsh, P. T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


Crown copyright 2007. Reproduced with the permission of the Controller of Her Majesty's Stationery Office. Published by Oxford University Press on behalf of the British Occupational Hygiene Society

Comparison of Portable, Real-Time Dust Monitors Sampling Actively, with Size-Selective Adaptors, and Passively

Andrew Thorpe* and Peter T. Walsh

Health and Safety Laboratory, Harpur Hill, Buxton, Derbyshire SK17 9JN, UK

* Author to whom correspondence should be addressed. Tel: +44-1298-218527; fax: +44-1298-218392; e-mail: andrew.thorpe{at}hsl.gov.uk

The performance of three, portable, real-time dust monitors was investigated inside a calm air dust chamber for a range of industrial dusts and two sizes of aluminium oxide dust. The instruments tested were the Split 2 (SKC Ltd), Microdust Pro (Casella Ltd) and DataRam (Thermo Electron Ltd), which sampled either passively or actively by connecting a manufacturer-supplied, size-selective adaptor and an air sampling pump to the inlet of the monitor. Two size-selective adaptors were tested with the Split 2: the GS-3 cyclone adaptor and the Institute of Occupational Medicine (IOM) inlet with porous foam inserts. Similarly, two size-selective adaptors were tested with the Microdust Pro: the Higgins–Dewell cyclone adaptor and the conical inhalable sampler (CIS) adaptor with porous foam inserts. The DataRam was tested with a GK 2.05 cyclone adaptor since there was no porous foam adaptor available. The instruments' responses were compared with the reference dust samplers: Casella Higgins–Dewell cyclone for the respirable fraction and IOM sampler for the inhalable fraction. The response of the dust monitors was found to be linear with respirable dust concentration when operated either passively or actively using the cyclone size-selective inlets. Their responses were, however, lower when operated actively with the cyclone adaptors compared to the passive operation and lower still when used with the porous foam inserts. There was also often more scatter in the porous foam measurements, attributable to variable clogging of the foams caused by inconsistent loading with dust. The dust monitor responses were sensitive to changes in particle size when operated passively but much less so in active mode with the cyclone adaptors. The Microdust Higgins–Dewell cyclone adaptor measurements agreed closely with the reference respirable concentration for all dusts, whereas those for the DataRam GK 2.05 and Split 2 GS-3 cyclone adaptors were different to the reference. Concentrations measured with the foam adaptors were considerably lower than both the reference cyclone samplers and the dust monitor cyclone adaptors and increasingly undersampled as they became loaded with dust. Inhalable dust measured with the Split 2 IOM adaptor agreed closely with the reference IOM inhalable samplers, whereas the Microdust CIS adaptor underestimated the inhalable concentration compared to the reference.

Keywords: active sampling • cyclone • inhalable dust • passive sampling • porous foam • real-time dust monitors • respirable dust

Received June 19, 2007; in final form August 21, 2007


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.