Skip Navigation


Annals of Occupational Hygiene Advance Access originally published online on March 15, 2007
Annals of Occupational Hygiene 2007 51(3):327-335; doi:10.1093/annhyg/mem004
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
51/3/327    most recent
mem004v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by HOLMéR, I.
Right arrow Articles by GAO, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by HOLMéR, I.
Right arrow Articles by GAO, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© The Author 2007. Published by Oxford University Press on behalf of the British Occupational Hygiene Society

Minute Volumes and Inspiratory Flow Rates During Exhaustive Treadmill Walking Using Respirators

INGVAR HOLMéR*, KALEV KUKLANE and CHUANSI GAO

Thermal Environment Laboratory, Division of Ergonomics, Department of Design Sciences Faculty of Engineering Lund University, Sweden

*Author to whom correspondence should be addressed. Tel: +46 46 2223932; fax: +46 46 2224431; e-mail: ingvar.holmer{at}design.lth.se

Air flow rate through filters and face masks is one important determinant of the final protection factor of a respiratory protective device in use. Respiratory minute volumes and instantaneous breath flow rates were measured in eight subjects during treadmill work using three types of filtering respirators and one control breathing mask. Work comprised five consecutive bouts of walking at 5 km/h with an increase in elevation of the treadmill by 5% every 5 min and a final walk at 6 km/h and 22.5%. Three subjects managed to complete 5 min at the final work rate. Minute ventilation increased in a curvilinear manner with oxygen uptake and reached 88 ± 20 and 93 ± 20 l/min at 5 km/h (20%) with the control mask and a half mask with filter (SP), respectively. Mean peak inspiratory flow rate (PIFR) was 273 ± 39 for Control and 300 ± 36 for SP at the same work rate. Two power assisted, positive pressure filter respirators (SA and SE) produced higher mask minute volumes at any given work rate compared to respiratory minute volumes in control and SP. PIFR in SA and SE were equal to or lesser than SP. During standardized speech communication, minute volumes decreased. In contrast, PIFR increased by about 100% at low work rates and about 30% at 5 km/h (20%) compared to no speech condition, reaching a highest value of 414 ± 46 l/min for SE. Filter testing is made at a constant flow rate of 95 l/min, a condition that eventually needs to be reconsidered in order to ensure a relevant and valid function test.

Keywords: exercise • metabolic rate • oxygen uptake • peak flow rate • ventilation


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.