Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by RÄISÄNEN, J.
Right arrow Articles by NIEMELÄ, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by RÄISÄNEN, J.
Right arrow Articles by NIEMELÄ, R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Ann. occup. Hyg., Vol. 46, No. 5, pp. 501-506, 2002
© 2002 British Occupational Hygiene Society
Published by Oxford University Press

On-line Monitoring of Solvent Emission Rates Using an Open Path FTIR Analyser

JOUNI RÄISÄNEN* and RAIMO NIEMELÄ

Finnish Institute of Occupational Health, Laajaniityntie 1, FIN-01620 Vantaa, Finland

Received 20 September 2001; in final form 18 March 2002

Solvent mixture concentrations in paint and resin manufacture were on-line monitored using a portable open path Fourier transform infrared (OP-FTIR) analyser in order to determine solvent emission rates into workspaces. The mean solvent emission rate was 0.46 kg/h in paint production and 0.35 kg/h in resin manufacture. Expressed as emission factor, i.e. evaporated portion of the total solvent mass used, the corresponding values were 0.01% for paint production and 0.1% for resin manufacture. The OP-FTIR instrument together with advanced spectra analysis software facilitated a rapid identification of solvent mixtures and on-line concentration monitoring with good temporal resolution. The analyser seems to be particularly useful in industrial hygiene applications where spatial average concentrations are needed. The further benefit of the open path instrument is that no sampling lines, pumps or sample cells are needed.

Keywords: open path FTIR; on-line monitoring; emission rates; solvent


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.