Ann. occup. Hyg., Vol. 41, No. 3, pp. 325-344, 1997
© 1997 British Occupational Hygiene Society
Published by Oxford University Press
research-article |
BIOAEROSOL EXPOSURE IN WASTE COLLECTION: A COMPARATIVE STUDY ON THE SIGNIFICANCE OF COLLECTION EQUIPMENT, TYPE OF WASTE AND SEASONAL VARIATION


*National Institute of Occupational Health Lersø Parkallé 105, DK-2100 Copenhagen, Denmark
Present address: Danish Veterinary Laboratory Bülowsvej 27, DK-l790 Copenhagen, Denmark
Author to whom correspondence should be addressed
Recent Danish studies on waste collectors' bioaerosol exposure are summarized. Generally the median exposure levels ranged from 105 to 106 cells m3 (total microorganisms), 104 to 105 cfu m3 (culturable fungi) and 103 to 104 cfu m3 (culturable bacteria). The type of waste was a governing factor for exposure. Garden waste collectors frequently experienced concentrations exceeding 105 cfu m3 for mesophilic fungi and 104 cfu m3 for the thermophilic fungus Aspergillus fumigatus, Workers collecting compostable, mixed and sorted waste occasionally experienced similar concentrations of the fungal groups while workers collecting bulky waste and paper had low exposure. Type of collection vehicle was identified as another governing factor for exposure. Vehicles loaded from the top (approximately 3 m above the ground) caused lower exposure (by a factor of 25) to fungi than vehicles loaded at the level or the breathing zone of the workers. Exposure was also affected by season of the yearthe concentration of total microorganisms, culturable fungi, Aspergillus fumigatus and endotoxin was low in winter. Exposure to total microorganisms counted by microscopy was found to have a fairly high validity (Va) as an indicator of exposure to culturable fungi (Va = 1·45) or culturable bacteria (Va = 1·25). Likewise, dust may also be used as an indicator of exposure to total microorganisms (Va = 1·36), culturable fungi (Va = 1·31) and culturable bacteria (Va = 1·35). © 1997 British Occupational Hygiene Society. Published by Elsevier Science Ltd
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
A. M. Madsen and A. K. Sharma Sampling of High Amounts of Bioaerosols Using a High-Volume Electrostatic Field Sampler Ann. Hyg., April 1, 2008; 52(3): 167 - 176. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. M. WOUTERS, S. SPAAN, J. DOUWES, G. DOEKES, and D. HEEDERIK Overview of Personal Occupational Exposure Levels to Inhalable Dust, Endotoxin, {beta}(1->3)-Glucan and Fungal Extracellular Polysaccharides in the Waste Management Chain Ann. Hyg., January 1, 2006; 50(1): 39 - 53. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. OPPLIGER, S. HILFIKER, and T. VU DUC Influence of Seasons and Sampling Strategy on Assessment of Bioaerosols in Sewage Treatment Plants in Switzerland Ann. Hyg., July 1, 2005; 49(5): 393 - 400. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. O. BREUM, T. SCHNEIDER, O. JORGENSEN, T. VALDBJORN RASMUSSEN, and S. SKIBSTRUP ERIKSEN Cellulosic Building Insulation versus Mineral Wool, Fiberglass or Perlite: Installer's Exposure by Inhalation of Fibers, Dust, Endotoxin and Fire-retardant Additives Ann. Hyg., November 1, 2003; 47(8): 653 - 669. [Abstract] [Full Text] [PDF] |
||||
![]() |
I M Wouters, S K M Hilhorst, P Kleppe, G Doekes, J Douwes, C Peretz, and D Heederik Upper airway inflammation and respiratory symptoms in domestic waste collectors Occup. Environ. Med., February 1, 2002; 59(2): 106 - 112. [Abstract] [Full Text] [PDF] |
||||
![]() |
C Glas, P Hotz, and R Steffen Hepatitis A in workers exposed to sewage: a systematic review Occup. Environ. Med., December 1, 2001; 58(12): 762 - 768. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Bünger, M. Antlauf-Lammers, T. G Schulz, G. A Westphal, M. M Müller, P. Ruhnau, and E. Hallier Health complaints and immunological markers of exposure to bioaerosols among biowaste collectors and compost workers Occup. Environ. Med., July 1, 2000; 57(7): 458 - 464. [Abstract] [Full Text] |
||||
![]() |
B. H. Nielsen, E. M. Nielsen, and N. O. Breum Seasonal variation in bioaerosol exposure during biowaste collection and measurements of leaked percolate Waste Management Research, February 1, 2000; 18(1): 64 - 72. [Abstract] [PDF] |
||||
![]() |
N. O. Breum, H. Wurtz, U. Midtgaard, and N. Ebbehoj Dustiness and bio-aerosol exposure in sorting recyclable paper Waste Management Research, April 1, 1999; 17(2): 100 - 108. [Abstract] [PDF] |
||||
![]() |
T. A. Reponen, S. V. Gazenko, S. A. Grinshpun, K. Willeke, and E. C. Cole Characteristics of Airborne Actinomycete Spores Appl. Envir. Microbiol., October 1, 1998; 64(10): 3807 - 3812. [Abstract] [Full Text] |
||||



