Skip Navigation



Annals of Occupational Hygiene Advance Access published online on October 7, 2009

Annals of Occupational Hygiene, doi:10.1093/annhyg/mep066
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Eypert-Blaison, C.
Right arrow Articles by Kauffer, E.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Eypert-Blaison, C.
Right arrow Articles by Kauffer, E.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2009. Published by Oxford University Press on behalf of the British Occupational Hygiene Society

Comparison of Direct and Indirect Methods of Measuring Airborne Chrysotile Fibre Concentration

Celine Eypert-Blaison*, Sylvie Veissiere, Olivier Rastoix and Edmond Kauffer

Institut National de Recherche et de Sécurité, Centre de Lorraine, Département Métrologie des Polluants, Laboratoire d'Analyses Inorganiques et de Caractérisation des Aérosols, Rue du Morvan, CS 60027, 54519 Vandoeuvre les Nancy Cedex, France

* Author to whom correspondence should be addressed. Tel: +33-3-83-50-87-19; fax: +33-3-83-50-20-60; e-mail: celine.eypert-blaison{at}inrs.fr

Transmission electron microscopy observations most frequently form a basis for estimating asbestos fibre concentration in the environment and in buildings with asbestos-containing materials. Sampled fibres can be transferred to microscope grids by applying either a direct [ISO (1995) Draft International ISO/DIS 10312. Ambient air. Determination of asbestos fibres. Direct transfer transmission electron microscopy procedure. Geneva, Switzerland: International Standardization Organization] or an indirect [AFNOR (1996) Détermination de la concentration en fibres d'amiante par microscopie électronique à transmission—Méthode indirecte. Cedex, France: AFNOR, p. 42; ISO (1997) Draft International ISO/DIS 13794. Ambient air. Determination of asbestos fibres. Indirect-transfer transmission electron microscopy procedure. Geneva, Switzerland: International Standardization Organization] method. In the latter case, ISO Standard 13794 recommends filtering calcination residues either on a polycarbonate (PC) filter (PC indirect method) or on a cellulose ester (CE) membrane (CE indirect method). The PC indirect method requires that fibres deposited on a PC filter be covered by a carbon layer, whereas in the CE indirect method, the CE membrane has to be directly processed using a method described in ISO Standard 10312. The purpose of this study was to compare results obtained using, on the one hand, direct preparation methods and, on the other hand, PC indirect or CE indirect methods, for counting asbestos fibres deposited on filters as a result of liquid filtration or air sampling. In direct method-based preparation, we observed that an etching time of 6–14 min does not affect the measured densities, except for fibres <1 µm deposited by liquid filtration. Moreover, in all cases, the direct method gives higher densities than the PC indirect method because of possible fibre disappearance when using the carbon evaporator implemented in the PC indirect method. The CE membrane used for sample preparation in the CE indirect method is collapsed prior to passing it through the carbon evaporator, so the fibres are less likely to disappear at this stage. We then note that the resulting fibre densities for chrysotile-loaded filters prepared using the direct method are close to those obtained with filters prepared using the CE indirect method. Our study therefore shows that, under the implemented experimental conditions, the PC and CE indirect preparation methods described in ISO Standard 13794 are not equivalent.

asbestos • cellulose ester (CE) filter • direct preparation • filters • indirect preparation • polycarbonate (PC) filter • transmission electron microscopy (TEM)

Received March 31, 2009; in final form July 20, 2009


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.