Skip Navigation


Annals of Occupational Hygiene Advance Access originally published online on October 17, 2008
Annals of Occupational Hygiene 2008 52(8):695-706; doi:10.1093/annhyg/men058
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Supplementary Data
Right arrow All Versions of this Article:
52/8/695    most recent
men058v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Demou, E.
Right arrow Articles by Hellweg, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Demou, E.
Right arrow Articles by Hellweg, S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© The Author 2008. Published by Oxford University Press on behalf of the British Occupational Hygiene Society

Exposure to Manufactured Nanostructured Particles in an Industrial Pilot Plant

Evangelia Demou*, Philippe Peter and Stefanie Hellweg

ETH Zurich, Institute of Environmental Engineering, Schafmattstrasse 6, 8093, Zurich, Switzerland

* Author to whom correspondence should be addressed. Tel: +41-44-63-23-172; fax: +41-44-63-31-061; e-mail: evangelia.demou{at}ifu.baug.ethz.ch

Objectives: Nanomaterial production and the number of people directly in contact with these materials are increasing. Yet, little is known on the association between exposure and corresponding risks, such as pulmonary inflammation and oxidative stress.

Methods: Condensation Particle Counters, a DustTrakTM and Scanning Mobility Particle SizerTM quantified real-time size, mass and number concentrations in a nanostructure particle pilot-scale production facility, using a high-temperature gas-phase process, over a 25-day period. Temporal and spatial analysis of particle concentrations and sizes was performed during production, maintenance and handling. Number-based particle retention of breathing mask filters used under real-time production and exposure conditions in the workplace was quantified.

Results: The results demonstrate elevated number concentrations during production, which can be an order of magnitude higher than background levels. Average concentrations during production were 59 100 cm–3 and 0.188 mg m–3 for submicron particles. Mask filters decreased particle number concentrations by >96%.

Conclusions: This study demonstrates real-time worker exposure during gas-phase nanoparticle manufacturing. Qualitative and quantitative analysis of emission sources and concentration levels in a production plant is accomplished. These results are important for workers, employers and regulators in the nanotechnology field as they provide information on encountered exposures and possibilities for mitigation measures.

Keywords: CPC • exposure • nanoparticles • particulate matter


The free full text of this article can be found in the online version of this issue.

Received February 7, 2008; in final form July 27, 2008


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
J R Soc InterfaceHome page
A. Seaton, L. Tran, R. Aitken, and K. Donaldson
Nanoparticles, human health hazard and regulation
J R Soc Interface, February 6, 2010; 7(Suppl_1): S119 - S129.
[Abstract] [Full Text] [PDF]


Home page
ANN OCCUP HYGHome page
E. Demou, W. J. Stark, and S. Hellweg
Particle Emission and Exposure during Nanoparticle Synthesis in Research Laboratories
Ann. Hyg., November 1, 2009; 53(8): 829 - 838.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.