Skip Navigation


Annals of Occupational Hygiene Advance Access originally published online on June 16, 2006
Annals of Occupational Hygiene 2006 50(7):679-691; doi:10.1093/annhyg/mel025
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
50/7/679    most recent
mel025v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by NEITZEL, R.
Right arrow Articles by SEIXAS, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by NEITZEL, R.
Right arrow Articles by SEIXAS, N.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© The Author 2006. Published by Oxford University Press on behalf of the British Occupational Hygiene Society

Variability of Real-World Hearing Protector Attenuation Measurements

RICHARD NEITZEL*, SEBRINA SOMERS and NOAH SEIXAS

Department of Environmental and Occupational Health Sciences, University of Washington Box 354695, Seattle, WA 98195-4695, USA

*Author to whom correspondence should be addressed. Tel: +1-206-221-5445; fax: +1-206-616-6240; e-mail: rneitzel{at}u.washington.edu

The attenuation provided by a hearing protection device (HPD) in the field is usually estimated by applying a derating factor to the laboratory-determined noise reduction rating (NRR) of the HPD. However, attenuation is highly dependent on individual-specific HPD fit. Prediction of an individual's attenuation depends on the accuracy of the measurement system and the variability of attenuation over time (e.g. after HPD refitting). Variability in attenuation and attenuation test systems has not been adequately characterized to allow for such an assessment. This study compared attenuation measurements made with two systems, Real-Ear-at-Threshold (REAT) and Microphone-in-Real-Ear (MIRE), on 20 workers using two earplugs (foam and custom-molded). Workers' perceptions of the earplugs were also evaluated. Individuals' attenuation results were summarized as personal attenuation ratings (PARs, similar to NRRs). Variability in PARs from between-subject, within-subject and within-day (i.e. repeated tests on a subject without earplug refitting) differences was assessed and used to present the lower confidence limit, or uncertainty factor (UF), of an average individual's attenuation. The custom-molded earplug PARs achieved a higher mean percentage of labeled attenuation than did the foam earplug with both test systems. The custom-molded earplugs also had higher overall acceptance among workers. MIRE PAR levels were lower than REAT levels for both earplugs, but the relationship between the two test systems was highly variable. The MIRE system had lower within-day variability than the REAT system. One individual's MIRE results were highly influential; removal of these results greatly reduced the UF for the custom-molded earplug/MIRE combination. UFs ranged from 8.8 to 13.5 dB. These findings highlight the importance of evaluating variability in individual-specific protection results for personal protective equipment like HPDs, rather than relying on single measurements.

Keywords: attenuation measurement • hearing protection • individual fit test • noise exposure • noise-induced hearing loss • variance components


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.