Skip Navigation


Annals of Occupational Hygiene Advance Access originally published online on December 14, 2005
Annals of Occupational Hygiene 2006 50(2):175-187; doi:10.1093/annhyg/mei057
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
50/2/175    most recent
mei057v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (5)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by MADSEN, A. M.
Right arrow Articles by SCHNEIDER, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by MADSEN, A. M.
Right arrow Articles by SCHNEIDER, T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© 2005 British Occupational Hygiene Society Published by Oxford University Press


Original Article

Characterization of Microbial Particle Release from Biomass and Building Material Surfaces for Inhalation Exposure Risk Assessment

A. M. MADSEN*, P. KRUSE and T. SCHNEIDER

National Institute of Occupational Health, Lersø Parkallé 104, 2100 Copenhagen, Denmark

* Author to whom correspondence should be addressed. Tel: 0045 39 16 52 42; fax: 0045 39 16 52 01; e-mail: amm{at}ami.dk

A conceptual approach including measurements of materials at rest (step 1), measurements using a large rotating drum (step 2) or a Particle-FLEC (step 2) and measurements at a workplace (step 4) has been used to characterize the release of microbial components (bacteria, fungi, actinomycetes, endotoxin or enzymes) and particles from straw, wood chips or fungal cultures of different ages on gypsum boards. Repeated agitation or handling periods were included in step 2 and step 4. There was a low similarity between the amount of microbial components measured in step 1 and the aerosolized amount (step 2) from gypsum boards, wood chips and straw. Ratios between some microbial components measured at the workplace (step 4) and measured in step 2, showed similarities. Less than 1.3% of the total amount of microorganisms and endotoxin becomes airborne during 5 min of agitation of straw or wood chips. Most microbial components were released at higher rates during the first agitation period than during the following periods. However, differences were seen between different microbial components, and endotoxin from straw was released at the same rate in two successive agitation periods. Fungal particles smaller than spores were released from fungal colonized gypsum boards at amounts that were up to 30 times higher in the first agitation period compared with that in the following period, while fungal spores were released at amounts that were five times as high in the first period compared with that in the following period. In addition to differences between microbial components, the release patterns of microbial components were different for wood chips and straw. The time for maximum particle release to half particle release was longer for straw than for wood chips. The observation that some components, e.g. endotoxin, are released at the same rate in two successive handling steps, and that others (e.g. fungi) are mainly released initially, shows that the exposure period to different components from the same material differs in duration. The observed differences in the release patterns of different components and the differences between materials are important when preventive steps are to be taken, and it stresses the importance of applying a relevant sampling time and period in exposure assessments.

Keywords: actinomycetes • bioaerosol • endotoxin • enzymes • fungi • dustiness • exposure • straw


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
ANN OCCUP HYGHome page
A. M. Madsen and A. K. Sharma
Sampling of High Amounts of Bioaerosols Using a High-Volume Electrostatic Field Sampler
Ann. Hyg., April 1, 2008; 52(3): 167 - 176.
[Abstract] [Full Text] [PDF]


Home page
ANN OCCUP HYGHome page
T. Schneider and K. A. Jensen
Combined Single-Drop and Rotating Drum Dustiness Test of Fine to Nanosize Powders Using a Small Drum
Ann. Hyg., January 1, 2008; 52(1): 23 - 34.
[Abstract] [Full Text] [PDF]


Home page
ANN OCCUP HYGHome page
A.M. MADSEN
Exposure to Airborne Microbial Components in Autumn and Spring During Work at Danish Biofuel Plants
Ann. Hyg., November 1, 2006; 50(8): 821 - 831.
[Abstract] [Full Text] [PDF]


Home page
ANN OCCUP HYGHome page
G. LIDEN
Dustiness testing of materials handled at workplaces.
Ann. Hyg., July 1, 2006; 50(5): 437 - 439.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.