Skip Navigation


Annals of Occupational Hygiene Advance Access originally published online on March 24, 2005
Annals of Occupational Hygiene 2005 49(6):481-492; doi:10.1093/annhyg/mei004
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
49/6/481    most recent
mei004v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (2)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by JONES, A. D.
Right arrow Articles by SAHLE, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by JONES, A. D.
Right arrow Articles by SAHLE, W.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© 2005 British Occupational Hygiene Society Published by Oxford University Press


Original Article

Thoracic Size-Selective Sampling of Fibres: Performance of Four Types of Thoracic Sampler in Laboratory Tests

A. D. JONES1,*, R. J. AITKEN1, J. F. FABRIÈS2, E. KAUFFER2, G. LIDEN3,{dagger}, A. MAYNARD4,{ddagger}, G. RIEDIGER5 and W. SAHLE3,§

1 Institute of Occupational Medicine (IOM), Research Park North, Riccarton, Edinburgh EH14 4AP, Scotland, UK; 2 Institut National de Recherche et de Securité (INRS), Paris, France; 3 National Institute for Working Life (NIWL), Stockholm, Sweden; 4 Health and Safety Laboratory (HSL), Sheffield, UK; 5 Berufsgenossenschaftliches Institut fur Arbeitssicherheit (BIA), Sankt Augustin, Germany

* Author to whom correspondence should be addressed. Tel: +44-870-850-51-31; fax: +44-870-850-51-32; e-mail: alan.jones{at}iomhq.org.uk

The counting of fibres on membrane filters could be facilitated by using size-selective samplers to exclude coarse particulate and fibres that impede fibre counting. Furthermore, the use of thoracic size selection would also remove the present requirement to discriminate fibres by diameter during counting. However, before thoracic samplers become acceptable for sampling fibres, their performance with fibres needs to be determined. This study examines the performance of four thoracic samplers: the GK2.69 cyclone, a Modified SIMPEDS cyclone, the CATHIA sampler (inertial separation) and the IOM thoracic sampler (porous foam pre-selector). The uniformity of sample deposit on the filter samples, which is important when counts are taken on random fields, was examined with two sizes of spherical particles (1 and 10 µm) and a glass fibre aerosol with fibres spanning the aerodynamic size range of the thoracic convention. Counts by optical microscopy examined fields on a set scanning pattern. Hotspots of deposition were detected for one of the thoracic samplers (Modified SIMPEDS with the 10 µm particles and the fibres). These hotspots were attributed to the inertial flow pattern near the port from the cyclone pre-separator. For the other three thoracic samplers, the distribution was similar to that on a cowled sampler, the current standard sampler for fibres. Aerodynamic selection was examined by comparing fibre concentration on thoracic samples with those measured on semi-isokinetic samples, using fibre size (and hence calculated aerodynamic diameter) and number data obtained by scanning electron microscope evaluation in four laboratories. The size-selection characteristics of three thoracic samplers (GK2.69, Modified SIMPEDS and CATHIA) appeared very similar to the thoracic convention; there was a slight oversampling (relative to the convention) for dae < 7 µm, but that would not be disadvantageous for comparability with the cowled sampler. Only the IOM thoracic sampler tended to undersample the fibres relative to the thoracic convention. With the data divided into four classes based on fibre length, the size-selection characteristics appeared to be unaffected by fibre length for GK2.69, Modified SIMPEDS and CATHIA. Only the IOM thoracic sampler (with the foam selector) showed slightly lower selection for longer length classes of fibres. These results indicate that the tested samplers follow the thoracic sampling convention for fibres, and may be used to improve the quality and reliability of samples that are taken when there is likely to be significant background dust.

Keywords: fibres • sampling • size-selective • thoracic


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
ANN OCCUP HYGHome page
E. G. Lee, M. Harper, J. Nelson, P. J. Hintz, and M. E. Andrew
A Comparison of the CATHIA-T Sampler, the GK2.69 Cyclone and the Standard Cowled Sampler for Thoracic Fiber Concentrations at a Taconite (Iron Ore)-Processing Mill
Ann. Hyg., January 1, 2008; 52(1): 55 - 62.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.