Skip Navigation


Annals of Occupational Hygiene Advance Access originally published online on January 24, 2005
Annals of Occupational Hygiene 2005 49(3):245-257; doi:10.1093/annhyg/meh097
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
49/3/245    most recent
meh097v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (8)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by LEE, S.-A.
Right arrow Articles by REPONEN, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by LEE, S.-A.
Right arrow Articles by REPONEN, T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


© 2005 British Occupational Hygiene Society Published by Oxford University Press;


Original Article

Laboratory and Field Evaluation of a New Personal Sampling System for Assessing the Protection Provided by the N95 Filtering Facepiece Respirators against Particles

SHU-AN LEE1, SERGEY A. GRINSHPUN1, ATIN ADHIKARI1, WEIXIN LI1, ROY MCKAY1, ANDREW MAYNARD2 and TIINA REPONEN1,*

1 Department of Environmental Health, University of Cincinnati, P.O. Box 670056, Cincinnati, OH 45267-0056, USA; 2 Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, 4676 Columbia Parkway, Cincinnati, OH 45226, USA

* Author to whom correspondence should be addressed. Tel: +1-513-558-0571; fax: +1-513-558-2263; e-mail: reponeta{at}ucmail.uc.edu

ABSTRACT

Objectives: We have recently developed a new personal sampling system for the real-time measurement of the protection provided by respirators against airborne dust and micro-organisms. The objective of this study was to evaluate the performance characteristics of the new sampling system in both laboratory and field conditions.

Methods: The measurements were conducted using the N95 filtering facepiece respirators and the newly developed personal sampling system put on a manikin (laboratory study) or donned by a human subject (laboratory and field studies). Two inhalation flow rates (0 and 40 l min–1) in conjunction with the sampling flow rate (10 l min–1) were tested in the manikin-based experiments to investigate the effects of the leak location (nose, cheek and chin) and the depth of the sampling probe (0, 5, 10 and 15 mm) within the respirator. The effect of human activity on the protection factor was evaluated using a variety of head movements and breathing patterns when a human subject wore the respirator in a room-size laboratory test chamber. The field study was conducted during corn harvesting with a respirator worn by a human subject on a combine.

Results: There was no significant difference in the protection factors for different leak locations, or for sampling probe depths, when the inhalation rate was 0 l min–1. For the inhalation rate of 40 l min–1, the protection factors for nose leaks were higher than those for chin and cheek leaks. Furthermore, the protection factor was the lowest and showed the least variation when the sampling probe depth was equal to 0 mm (imbedded on the respirator surface). Human subject testing showed that the grimace maneuver decreased the protection factor and changed the original respirator fit. The protection factor during breath holding was lower than that found during inhalation and exhalation. Field results showed greater variation than laboratory results.

Conclusions: The newly designed personal sampling system efficiently detected the changes in protection factors in real time. The sampling flow was least affected by the inhalation flow when the sampling probe was imbedded on the respirator surface. Leak location, breathing patterns and exercises did affect the measurement of the protection factors obtained using an N95 filtering facepiece respirator. This can be attributed to the differences in the in-mask airflow dynamics contributed by the leak, filter material, sampling probe and inhalation. In future studies, it would be beneficial if the laboratory data could be integrated with the field database.

Keywords: breathing pattern • depth of the sampling probe • fit testing • leak location • leak size • protection factor • respirator


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
ANN OCCUP HYGHome page
K. J. Cho, T. Reponen, R. Mckay, R. Shukla, H. Haruta, P. Sekar, and S. A. Grinshpun
Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow
Ann. Hyg., August 21, 2009; (2009) mep062v1.
[Abstract] [Full Text] [PDF]


Home page
ANN OCCUP HYGHome page
E. Demou, P. Peter, and S. Hellweg
Exposure to Manufactured Nanostructured Particles in an Industrial Pilot Plant
Ann. Hyg., November 1, 2008; 52(8): 695 - 706.
[Abstract] [Full Text] [PDF]


Home page
ANN OCCUP HYGHome page
S.-A. Lee, S. A. Grinshpun, and T. Reponen
Respiratory Performance Offered by N95 Respirators and Surgical Masks: Human Subject Evaluation with NaCl Aerosol Representing Bacterial and Viral Particle Size Range
Ann. Hyg., April 1, 2008; 52(3): 177 - 185.
[Abstract] [Full Text] [PDF]


Home page
ANN OCCUP HYGHome page
R. NEITZEL, S. SOMERS, and N. SEIXAS
Variability of Real-World Hearing Protector Attenuation Measurements
Ann. Hyg., October 1, 2006; 50(7): 679 - 691.
[Abstract] [Full Text] [PDF]


Home page
ANN OCCUP HYGHome page
A. BALAZY, M. TOIVOLA, T. REPONEN, A. PODGORSKI, A. ZIMMER, and S. A. GRINSHPUN
Manikin-Based Performance Evaluation of N95 Filtering-Facepiece Respirators Challenged with Nanoparticles
Ann. Hyg., April 1, 2006; 50(3): 259 - 269.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.