Skip Navigation

This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (2)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by MÄKELÄ, E. A.
Right arrow Articles by PELTONEN, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by MÄKELÄ, E. A.
Right arrow Articles by PELTONEN, K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Ann. occup. Hyg., Vol. 47, No. 4, pp. 313-323, 2003
© 2003 British Occupational Hygiene Society
Published by Oxford University Press

The Permeability of Surgical Gloves to Seven Chemicals Commonly Used in Hospitals

ERJA A. MÄKELÄ*, SINIKKA VAINIOTALO and KIMMO PELTONEN§

Finnish Institute of Occupational Health, Department of Industrial Hygiene and Toxicology, Topeliuksenkatu 41 a A, FIN-00250 Helsinki, Finland

Received 1 July 2002; in final form 17 December 2002

Disinfectants may cause adverse effects directly on the skin or systemically by permeating through the skin. In this study breakthrough times were measured for surgical gloves with chemicals which are commonly used in healthcare. Classical methods of analytical chemistry were tailored for the permeation tests, which were carried out according to the European standard EN 374 and the American standard ASTM F739. An exception to the EN 374 standard was made by using a 4 h testing time instead of 8 h. The gloves did not exhibit permeation of potassium hydroxide (45%), sodium hypochlorite (13%) or hydrogen peroxide (30%). Furthermore, neither glutaraldehyde (2%) nor chlorhexidine digluconate (4%) in the commercial disinfectant solutions studied exhibited permeation. Slight permeation of peracetic acid (0.35%) and acetic acid (4%) from a disinfectant agent was observed through single layered natural rubber materials. Clear evidence of formaldehyde permeation was detected through single layered natural rubber gloves, where the ASTM breakthrough times were 17–67 min, but the permeation rates were not high enough for breakthrough to have occurred according to the EN standard. The gloves in this study which offered most protection from chemical permeation were the chloroprene gloves and the thick double layered natural rubber gloves.

Keywords: chemicals; disinfectants; gloves; permeation; surgical


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
ANN OCCUP HYGHome page
E. A. MAKELA, S. VAINIOTALO, and K. PELTONEN
Permeation of 70% Isopropyl Alcohol Through Surgical Gloves: Comparison of the Standard Methods ASTM F739 and EN 374
Ann. Hyg., June 1, 2003; 47(4): 305 - 312.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.